Close

1. Identity statement
Reference TypeConference Paper (Conference Proceedings)
Siteplutao.sid.inpe.br
Holder Codeisadg {BR SPINPE} ibi 8JMKD3MGPCW/3DT298S
Identifier8JMKD3MGP3W/3Q6CCJP
Repositorysid.inpe.br/plutao/2017/12.07.15.53
Last Update2020:11.26.14.32.14 (UTC) simone
Metadata Repositorysid.inpe.br/plutao/2017/12.07.15.53.05
Metadata Last Update2020:11.26.14.32.15 (UTC) simone
ISBN1983-7402
Labellattes: 2061452556577317 1 RangelBarr:2017:MaDiMa
Citation KeyRangelRossBarrScha:2017:LoInEf
TitleLoad influence in the efficiency of a low voltage capacitive nonlinear transmission line
Year2017
Access Date2024, May 18
Secondary TypePRE CN
Number of Files1
Size8196 KiB
2. Context
Author1 Rangel, Elizete Goncalves Lopes
2 Rossi, José Osvaldo
3 Barroso, Joaquim J.
4 Schamiloglu, E.
Resume Identifier1 8JMKD3MGP5W/3C9JH26
2 8JMKD3MGP5W/3C9JHJ5
Group1 LABAP-COCTE-INPE-MCTIC-GOV-BR
2 LABAP-COCTE-INPE-MCTIC-GOV-BR
Affiliation1 Instituto Nacional de Pesquisas Espaciais (INPE)
2 Instituto Nacional de Pesquisas Espaciais (INPE)
Author e-Mail Address1 elizete.rangel@inpe.br
2 jose.rossi@inpe
Conference NameSimpósio de Aplicações Operacionais em Áreas de Defesa, 19
Conference LocationSão José dos Campos - SP
Date26-28 set.
Book TitleAnais
Tertiary TypeArtigo
History (UTC)2017-12-07 15:53:05 :: lattes -> administrator ::
2018-06-04 23:26:37 :: administrator -> simone :: 2017
3. Content and structure
Is the master or a copy?is the master
Content Stagecompleted
Transferable1
Content TypeExternal Contribution
AbstractSeveral works on Nonlinear transmission lines (NLTLs) have demonstrated their suitability for application in communication systems, these applications involve techniques for forming and sharpening a short electrical pulse to achieve pulse compression, frequency multiplier, phase shifter, pulsed radar, battlefield communication disruption and also RF generation, holding a great potential for replacing vacuum electron tubes as a low cost and fully solid state technology. This paper addresses the influence of the load termination on the efficiency of a low voltage NLTL. The performance was assessed by simulation with the software LT-Spice. The efficiency of the capacitive NLTL was evaluated by the analysis of the signals in frequency domain by calculating the percentage ratio of output to input energy of the Fast Fourier Transform (FFT) input and output signals. The analysis of frequency domain signals shows that RF conversion efficiency is affected by the load termination. The increase of the load resistor value from 390 W to 50 kW caused the rise of the RF efficiency conversion from 4.4 to 19.3 %. For a reactive load the RF efficiency is maximized with a resistor of 1kW and an inductor of 6 mH reaching the value of 14.7 %.
AreaFISPLASMA
Arrangementurlib.net > BDMCI > Fonds > Produção anterior à 2021 > LABAP > Load influence in...
doc Directory Contentaccess
source Directory Contentthere are no files
agreement Directory Content
agreement.html 07/12/2017 13:53 1.0 KiB 
4. Conditions of access and use
data URLhttp://urlib.net/ibi/8JMKD3MGP3W/3Q6CCJP
zipped data URLhttp://urlib.net/zip/8JMKD3MGP3W/3Q6CCJP
Languagept
Target Filerangel_load.pdf
User Grouplattes
Reader Groupadministrator
simone
Visibilityshown
Update Permissionnot transferred
5. Allied materials
Next Higher Units8JMKD3MGPCW/3ET2RFS
Citing Item Listsid.inpe.br/mtc-m21/2012/07.13.14.45.13 2
sid.inpe.br/mtc-m21/2012/07.13.14.52.24 2
sid.inpe.br/bibdigital/2013/09.25.21.49 2
URL (untrusted data)http://www.sige.ita.br/anais/XIXSIGE/index.htm
Host Collectiondpi.inpe.br/plutao@80/2008/08.19.15.01
6. Notes
NotesSetores de Atividade: Pesquisa e desenvolvimento científico.
Empty Fieldsarchivingpolicy archivist callnumber copyholder copyright creatorhistory descriptionlevel dissemination doi e-mailaddress edition editor format issn keywords lineage mark mirrorrepository nextedition numberofvolumes orcid organization pages parameterlist parentrepositories previousedition previouslowerunit progress project publisher publisheraddress readpermission rightsholder schedulinginformation secondarydate secondarykey secondarymark serieseditor session shorttitle sponsor subject tertiarymark type versiontype volume