1. Identity statement | |
Reference Type | Conference Paper (Conference Proceedings) |
Site | plutao.sid.inpe.br |
Holder Code | isadg {BR SPINPE} ibi 8JMKD3MGPCW/3DT298S |
Identifier | 8JMKD3MGP3W/3Q6CCJP |
Repository | sid.inpe.br/plutao/2017/12.07.15.53 |
Last Update | 2020:11.26.14.32.14 (UTC) simone |
Metadata Repository | sid.inpe.br/plutao/2017/12.07.15.53.05 |
Metadata Last Update | 2020:11.26.14.32.15 (UTC) simone |
ISBN | 1983-7402 |
Label | lattes: 2061452556577317 1 RangelBarr:2017:MaDiMa |
Citation Key | RangelRossBarrScha:2017:LoInEf |
Title | Load influence in the efficiency of a low voltage capacitive nonlinear transmission line |
Year | 2017 |
Access Date | 2024, May 18 |
Secondary Type | PRE CN |
Number of Files | 1 |
Size | 8196 KiB |
|
2. Context | |
Author | 1 Rangel, Elizete Goncalves Lopes 2 Rossi, José Osvaldo 3 Barroso, Joaquim J. 4 Schamiloglu, E. |
Resume Identifier | 1 8JMKD3MGP5W/3C9JH26 2 8JMKD3MGP5W/3C9JHJ5 |
Group | 1 LABAP-COCTE-INPE-MCTIC-GOV-BR 2 LABAP-COCTE-INPE-MCTIC-GOV-BR |
Affiliation | 1 Instituto Nacional de Pesquisas Espaciais (INPE) 2 Instituto Nacional de Pesquisas Espaciais (INPE) |
Author e-Mail Address | 1 elizete.rangel@inpe.br 2 jose.rossi@inpe |
Conference Name | Simpósio de Aplicações Operacionais em Áreas de Defesa, 19 |
Conference Location | São José dos Campos - SP |
Date | 26-28 set. |
Book Title | Anais |
Tertiary Type | Artigo |
History (UTC) | 2017-12-07 15:53:05 :: lattes -> administrator :: 2018-06-04 23:26:37 :: administrator -> simone :: 2017 |
|
3. Content and structure | |
Is the master or a copy? | is the master |
Content Stage | completed |
Transferable | 1 |
Content Type | External Contribution |
Abstract | Several works on Nonlinear transmission lines (NLTLs) have demonstrated their suitability for application in communication systems, these applications involve techniques for forming and sharpening a short electrical pulse to achieve pulse compression, frequency multiplier, phase shifter, pulsed radar, battlefield communication disruption and also RF generation, holding a great potential for replacing vacuum electron tubes as a low cost and fully solid state technology. This paper addresses the influence of the load termination on the efficiency of a low voltage NLTL. The performance was assessed by simulation with the software LT-Spice. The efficiency of the capacitive NLTL was evaluated by the analysis of the signals in frequency domain by calculating the percentage ratio of output to input energy of the Fast Fourier Transform (FFT) input and output signals. The analysis of frequency domain signals shows that RF conversion efficiency is affected by the load termination. The increase of the load resistor value from 390 W to 50 kW caused the rise of the RF efficiency conversion from 4.4 to 19.3 %. For a reactive load the RF efficiency is maximized with a resistor of 1kW and an inductor of 6 mH reaching the value of 14.7 %. |
Area | FISPLASMA |
Arrangement | urlib.net > BDMCI > Fonds > Produção anterior à 2021 > LABAP > Load influence in... |
doc Directory Content | access |
source Directory Content | there are no files |
agreement Directory Content | |
|
4. Conditions of access and use | |
data URL | http://urlib.net/ibi/8JMKD3MGP3W/3Q6CCJP |
zipped data URL | http://urlib.net/zip/8JMKD3MGP3W/3Q6CCJP |
Language | pt |
Target File | rangel_load.pdf |
User Group | lattes |
Reader Group | administrator simone |
Visibility | shown |
Update Permission | not transferred |
|
5. Allied materials | |
Next Higher Units | 8JMKD3MGPCW/3ET2RFS |
Citing Item List | sid.inpe.br/mtc-m21/2012/07.13.14.45.13 2 sid.inpe.br/mtc-m21/2012/07.13.14.52.24 2 sid.inpe.br/bibdigital/2013/09.25.21.49 2 |
URL (untrusted data) | http://www.sige.ita.br/anais/XIXSIGE/index.htm |
Host Collection | dpi.inpe.br/plutao@80/2008/08.19.15.01 |
|
6. Notes | |
Notes | Setores de Atividade: Pesquisa e desenvolvimento científico. |
Empty Fields | archivingpolicy archivist callnumber copyholder copyright creatorhistory descriptionlevel dissemination doi e-mailaddress edition editor format issn keywords lineage mark mirrorrepository nextedition numberofvolumes orcid organization pages parameterlist parentrepositories previousedition previouslowerunit progress project publisher publisheraddress readpermission rightsholder schedulinginformation secondarydate secondarykey secondarymark serieseditor session shorttitle sponsor subject tertiarymark type versiontype volume |
|
7. Description control | |
e-Mail (login) | simone |
update | |
|